Remote jack (CI-V) information

D CI-V connection example
The transceiver can be connected through an optional
CT-17
-
ci
v level converter
RS-232C port. The Icom Communications Interface-V
(CI-V) controls the transceiver.
Up to 4 Icom CI-V transceivers or receivers can be con-
nected to the PC. See page 12-56 for setting the CI-V
condition using the set mode.
D Data format
The CI-V system uses the following data formats. Data
formats differ depending on command numbers. A data
area or sub command is added to some commands.
Controller to ID-5100A/E
q
FE FE
8C
FE FE
q
ID-5100A/E to controller
to a PC equipped with an
w
e
r
t
E0
Cn
Sc
Data area
E0
8C
Cn
Sc
Data area
w
e
r
t
3 conductor
3.5 (d) mm plug
• Connections (ID-5100A/E side)
3.5 (d) mm
*No speaker is necessary for the CT-17 side.
OK message to controller
y
u
FD
FE FE
FD
FE FE
y
u
NG message to controller
13-16
Power source
DC 9–15 V
RS-232C
cable
CT-17
2 conductor
to [SP2]
3.5 (d) mm plug
SP
SP
GND
I/O
E0
8C
FB
FD
E0
8C
FA
FD
PC
GND
SP
I/O