Section
5.
PROGRAMMING
THE
SYSTEM
Note:
It is possible to program the system at any time, even at the installer's
premises prior to the actual installation. Simply apply power temporarily to
the control and then program the unit as desired.
THE
SECURITY
CONTROL
IS PROGRAMMED
VIA A
5137AD
OR
6139
ALPHA
CONSOLE
(or a download)
These consoles need not necessarily remain in the system after programming.
Note:
These addressable consoles must be set to their non-addressable mode
(device ID 31).
The initial sequence of entries should follow the order on the programming
sheet.
Certain programming fields, such as those used to select the expansion devices
(fields *22 and *25) must be programmed before expansion zones can be pro-
grammed. \f an expansion unit type is changed, the expansion zones should be
reprogrammed.
When programming, the field number will be displayed on the LCD display; also,
each entry is displayed as it is keyed in. After programming, values that have been
entered in each field can be reviewed and, if necessary, modified.
When programming from the console, note the following:
1.
Enter the Programming mode by simultaneously depressing the [*] and [#]
keys within
50 seconds
after power
is applied
to the Control, or
subsequently by keying the code 4 + 1+ 1+ 1 followed by depression of
CODE + 0 keys. If a different Master code is subsequently programmed,
use it instead of 4111 to gain access to the Programming mode. /f the Pro-
gramming mode was exited previously using a *98, it will prevent entry into
the Programming mode by the use of the Master Code + CODE + 0.
2.
Immediately following entry into the program mode, field *20 will be displayed.
Following the above display, the system is ready to accept entries for field
*20.
3.
To program a data field, key [*] plus Field No. (for example, *21), then
make the required entry.
Some entries require sequential pressings of [*] to actually enter the data. This is
true in the Zone and Relay fields *56, *80, and *81 and the prompts will indicate
this. Entry of [#] will generally back up one entry position for review.
4.
To simply review a data field, key [#] plus Field No.. Data will either be au-
tomatically sequentially displayed or can be displayed by successively press-
ing [#]. No changes will be accepted in this mode.
5.
When a data field has been completely programmed, the console will normally
"beep" three times and then automatically display the next data field number
to be programmed (if not, key [*] plus the Field No. of the next field to be
programmed).
6.
If the number of digits that you enter in the data field is less than the maximum
permitted (for example, phone number), then the console will display the last
data entered. To proceed, the next data field number to be programmed
must then be entered (for example, *42).
7.
Ifa field is improperly entered, the console will display EE. Simply re-enter
[*] or [#] plus the field number.
-16-