About the VISTA-10SEa
The VISTA-10SEa is a control that supports up to 22 zones using basic wired and/or wireless
expansion, plus remote keypads.
Basic Wired Zones
Provides 6 basic wired zones having the following characteristics:
Zones 1–6: response time is 300–500 milliseconds.
Zone 3: programmable for fast response time (10 milliseconds).
EOLR supervision supporting N.O. or N.C. sensors.
Zone 5: supports as many 4-wire smoke or heat detectors as can be powered from the
control).
Zone 7, 95, and 96: keypad Panics.
Zone 8: Duress.
Zone 9: Expansion module failure/trouble.
Optional Expansion Zones (up to 16 total, wired and wireless zones)
Wired Expansion:
Supports up to 8 additional wired zones using a 4219 Expansion Module or 4229
Expansion/Relay Module.
Zones have the following characteristics:
EOLR supervision supporting N.O. or N.C. sensors.
300–500mSec normal response with an option for fast (10–15mSec) response on loop A
(first expansion zone).
Wireless Expansion :
Supports up to 16 wireless zones (fewer, if using wired expansion zones).
Requires the use of a 5881-type receiver (with 5800 Series wireless transmitters), as
shown below.

General Description

Quick Arm Feature
Optional Output Relays
Optional Phone Module
Alarm Output
Auxiliary Power Output
Programming