User Groups (Pr. 160, Pr. 172 To Pr. 174) - Mitsubishi Electric FR-E700 Instruction Manual

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
6.17.4

User groups (Pr. 160, Pr. 172 to Pr. 174)

Parameter which can be read from the operation panel and parameter unit can be restricted.
In the initial setting, only the simple mode parameters are displayed.
Pr.
Name
No.
160
User group read selection
User group registered
172
display/batch clear
User group
173
registration
174
User group clear
The above parameter can be set when Pr. 160 "User group read selection" = 0.
The values read from Pr. 173 and Pr. 174 are always "9999".
Display of simple mode parameters and extended parameters (Pr. 160)
When Pr. 160 = "9999", only the simple mode parameters can be displayed on the operation
panel and parameter unit (FR-PU04/FR-PU07). (Refer to the parameter list Tab. 6-1 for the
simple mode parameters.)
Setting "0" to Pr. 160 enables the display of the simple mode parameters and extended para-
meters.
NOTES
When a plug-in option is fitted to the inverter, the option parameters can also be read.
When reading the parameters using the communication option, all parameters (simple mode,
extended mode, parameters for options) can be read regardless of the Pr. 160 setting.
When RS-485 communication is used to read the parameters, all parameters can be read,
regardless of the Pr. 550 "NET mode operation command source selection", Pr. 551 "PU
mode operation command source selection", regardless of Pr. 160 setting.
(auto-detect)
(initial value)
Pr. 15 "Jog frequency", Pr. 16 "Jog acceleration/deceleration time", and Pr. 991 "PU contrast
adjustment" are displayed as simple mode parameter when the parameter unit (FR-PU04/
FR-PU07) is fitted.
FR-E700 EC
Initial
Setting
Description
Setting
Range
Only the simple mode parameters can be
9999
displayed.
The simple mode and extended parame-
9999
0
ters can be displayed.
Only parameters registered in the user
1
group can be displayed.
Displays the number of cases registered
(0–16)
as a user group (Read only)
0
9999
Batch clear the user group registration
0–999/
Set the parameter numbers to be
9999
9999
registered to the user group.
0–999/
Set the parameter numbers to be cleared
9999
9999
from the user group.
Pr. 551
2 (PU)
0 (communication option)
3 (USB)
9999
Misoperation prevention and parameter setting restriction
Pr. 550
2 (PU)
9999
(auto-detect)
(initial value)
Parameters referred to
550
NET mode opera-
tion command
source selection
551
PU mode operation
command source
selection
Pr. 160 Valid/Invalid
Valid
Valid
Invalid (all readable)
With communication option: valid
Without communication option: invalid
(all readable)
Refer to
Section
6.18.3
6.18.3
6 - 195

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740Fr-e700 seriesFr-e720s ecFr-e740 ec