Parameter
6.19.6

USB communication (Pr. 547, Pr. 548)

Inverter setup can be easily performed using the FR Configurator by connecting the inverter and
personal computer with a USB cable. A personnel computer and inverter can be easily con-
nected with one USB cable.
Pr. No. Name
USB communication
547
station number
USB communication
548
check time interval
Changed setting value is made valid when powering on or resetting the inverter.
Specification
Interface
Transmission speed
Wiring Length
Connector
Power supply
Tab. 6-101: USB communication specifications
Fig. 6-131: Connection to the USB connector
You can perform parameter setting and monitoring with the FR Configurator. Refer to the in-
struction manual of the FR Configurator for details.
FR-E700 EC
Initial
Setting
Description
Value
Range
0
0–31
Inverter station number specification
USB communication is possible
0
Trips in the PU operation mode (E.USB)
Sets the interval of communication
check time. If a no-communication state
9999
0.1–999.8s
persists for longer than the permissible
time, the inverter will come to trip
(E.USB).
9999
No communication check
USB cable
USB connector
How to open the USB connector cover
Pull the cover in the direction of arrow.
Communication operation and setting
Parameters referred to
551
PU mode operation
command source
selection
Description
Conforms to USB1.1
12Mbps
5m
USB mini B connector (receptacle mini B type)
Self-power supply
Then turn it upward.
Refer to
Section
6.18.3
I001921E
6 - 269