Selection of operation mode and operation location
Selection of control source in network operation mode (Pr. 338, Pr. 339)
As control sources, there are the operation command source that controls the signals related to
the inverter start command and function selection and the speed command source that controls
the signals related to frequency setting.
In network operation mode, the commands from the external terminals and communication (PU
connector or communication option) are as listed below.
Communication operation com-
mand source (Pr. 338)
Operation
Location
Communication speed command
Selection
source (Pr.339)
Running frequency from
Fixed func-
communication
tion
(Terminal-
Terminal 2
equivalent
function)
Terminal 4
Low speed operation com-
0
RL
mand/remote setting clear/
stop-on contact selection 0
Middle-speed operation
1
RM
command/remote setting
deceleration
High speed operation
2
RH
command/remote setting
acceleration
Second function selection/
3
RT
stop-on contact selection 1
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
7
OH
External thermal relay input
8
REX
Fifteen speed selection
Inverter operation enable sig-
10
X10
nal
PU operation external
12
X12
interlock
14
X14
PID control valid terminal
Brake opening completion sig-
15
BRI
nal
PU-external operation switch-
16
X16
over
18
X18
V/f switching
Tab. 6-62:
Writing operation and speed commands (1)
6 - 218
0: NET
1:
2:
0: NET
Exter-
Exter-
nal
nal
NET
NET
External
External
NET
External
NET
External
NET
External
NET
Combined
External
NET
External
External
External
NET
External
NET
External
NET
1: External
1:
2:
0: NET
Exter-
Exter-
nal
nal
NET
NET
External
External
NET
External
NET
External
NET
External
External
Combined
External
NET
External
NET
External
NET
External
Parameter
Remarks
Pr. 59 = 0
(multi-speeds)
Pr. 59 = 1, 2
(remote)
Pr. 270 = 1
(stop-on-contact 0)
Pr. 270 = 1
(stop-on-contact 1)
Pr. 59 = 0
(multi-speeds)