Change The Frequency (40Hz) Of The Maximum Value Of Potentiometer (At 5V) - Mitsubishi Electric FR-E700 Instruction Manual

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

External operation
5.3.4

Change the frequency (40Hz) of the maximum value of potentiometer (at 5V)

Example
The frequency of the maximum analog voltage of the potentiometer (at 5V) has to be
changed from the initial setting of 50Hz to 40 Hz. Set 40Hz in Pr. 125.
Turn the digital dial until P.125 (Pr. 125) appears.
Press the SET key to show the currently set value.
The initial value "50.00" (50.00Hz) appears.
Turn the digital dial to change the set value to
"40.00" (40.00Hz).
Press the SET key to set.
Press the MODE key twice to choose monitor/
frequency monitor.
Turn the start switch (STF or STR) on and turn the
volume (frequency setting potentiometer)
clockwise to full slowly. (Refer to Fig. 5-27,
step
Fig. 5-28: Change the frequency of the maximum analog value
NOTES
Set the frequency at 0V using calibration parameter C2.
As other adjustment methods of frequency setting voltage gain, there are methods to adjust
with a voltage applied to across terminals 2-5 and adjust at any point without a voltage
applied. (Refer to section 6.16.3 for the setting method of calibration parameter C4.)
5 - 38
Operation
to
).
Initial value
50Hz
Bias
C2 (Pr. 902)
0
Frequency setting signal
0
0
C3 (Pr. 902)
Gain
Pr. 125
100%
5V
10V
C4 (Pr. 903)
Basic settings
Display
Flicker ... 40Hz output at 5V
input complete!
I001780E