Parameter
Parameter
Func-
Name
tion
DU/PU main display
52
data selection
AM terminal function
158
selection
Watt-hour meter clear
170
Operation hour meter
171
clear
Monitor decimal digits
268
selection
Energizing time
563
carrying-over times
Operating time
564
carrying-over times
Tab. 6-1:
Parameter overview (7)
FR-E700 EC
Incre-
Initial
Setting
ments
value
range
0/5/7–12/
14/20/
1
0
23–25/
52–57/61/
62/100
1–3/5/7–12/
1
1
14/21/24/
52/53/61/62
0
10
1
9999
9999
1
9999
0/9999
0
1
9999
1
9999
1
0
0–65535
1
0
0–65535
Description
Selects monitor to be displayed on
the operation panel and parameter
unit and monitor to be output to
the terminal AM.
0:
Output frequency (Pr. 52)
1:
Output frequency (Pr. 158)
2:
Output current (Pr. 158)
3:
Output voltage (Pr. 158)
5:
Frequency setting value
7:
Motor torque
8:
Converter output voltage
9:
Regenerative brake duty
10: Electronic thermal relay
function load factor
11: Output current peak value
12: Converter output voltage
peak value
14: Output power
20: Cumulative energization
time (Pr. 52)
21: Reference voltage output
(Pr. 158)
23: Actual operation time (Pr. 52)
24: Motor load factor
25: Cumulative power (Pr. 52)
52: PID set point
53: PID measured value
54: PID deviation (Pr. 52)
55: I/O terminal status (Pr. 52)
56: Option input terminal status
(Pr. 52)
57: Option output terminal status
(Pr. 52)
61: Motor thermal load factor
62: Inverter load factor
100:Set frequency is displayed
during a stop and output
frequency is displayed during
operation (Pr. 52).
Set "0" to clear the watt-hour meter
monitor.
Set the maximum value when
monitoring from communication
to 0 to 9999kWh.
Set the maximum value when
monitoring from communication
to 0 to 65535kWh.
Set "0" in the parameter to clear
the watt hour monitor.
Setting "9999" has no effect.
Displays the monitor as integral
value.
Displays the monitor in incre-
ments of 0.1.
No fixed decimal position
The numbers of cumulative ener-
gizing time monitor exceeded
65535h is displayed.
Reading only
The numbers of operation time
monitor exceeded 65535h is dis-
played.
Reading only
Parameter overview
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-138
6 - 7