Mitsubishi Electric FR-E700 Instruction Manual page 385

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
No. Item
9
Parameters
10
Link parameter extended
11
setting
Second parameter
changing
12
(instruction code
HFF = 1, 9)
Tab. 6-73: Setting of the instruction codes and data (3)
NOTES
Refer to page 6-234 for data formats A, A1, A2, B, C, D, E, E1 and E2.
Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
For the instruction codes HFF, HEC and HF3, their values are held once written but cleared
to zero when an inverter reset or all clear is performed.
FR-E700 EC
Read/
Instruction
Data Description
Code
write
Refer to the instruction code of the parame-
ter list (appendix) and write and/or read
Read
H00 to H63
parameter values as required.
When setting Pr. 100 and later, link param-
eter extended setting must be set.
Data format of Pr. 37 read and write is E2
and A2.
Write
H80 to HE3
Parameter description is changed accord-
Read
H7F
ing to the H00 to H09 setting.
For details of the settings, refer to the
instruction code of the parameter list
Write
HFF
(appendix).
Setting calibration parameter
Read
H6C
Write
HEC
Communication operation and setting
H00: Frequency
H01: Parameter-set analog value
H02: Analog value input from terminal
Refer to the list of calibration parameters
on page 6-246.
The gain frequency can also be written
using Pr. 125 (instruction code: H99) or
Pr. 126 (instruction code: H9A).
Number
of Data
Digits
(Format)
4
(B, E/D)
6
(B, E,
E2/D)
4
(A, C/D)
6
(A, A'2,
C/D)
2
(B, E1/D)
2
(A1, C/D)
2
(B, E1/D)
2
(A1, C/D)
6 - 245