Parameter
Parameter
Func-
Name
tion
Stop-on contact
270
control selection
Stop-on contact
excitation current
275
low-speed multiplying
factor
PWM carrier
276
frequency at stop-on
contact
277
Refer to Pr. 22
Brake opening
278
frequency
279
Brake opening current
Brake opening current
280
detection time
Brake operation time at
281
start
Brake operation
282
frequency
Brake operation time at
283
stop
Automatic accelera-
292
tion/deceleration
286
Droop gain
Droop filter time
287
constant
Tab. 6-1:
Parameter overview (25)
FR-E700 EC
Incre-
Initial
Setting
ments
value
range
0
1
0
1
0–300 %
0,1 %
9999
9999
0–9
1
9999
9999
0.01Hz
3Hz
0–30Hz
0.1%
130%
0–200%
0.1s
0.3s
0–2s
0.1s
0.3s
0–5s
0.01Hz
6Hz
0–30Hz
0.1s
0.3s
0–5s
1
0
0/1/7/8/11
0
0.1%
0%
0.1–100%
0.01s
0.3s
0–1s
Description
Without stop-on contact control
Stop-on contact control
Usually set a value between 130%
and 180%.
Set the force (holding torque) for
stop-on contact control.
No compensation.
Set a PWM carrier frequency for
stop-on contact control.
(Valid at the output frequency of
3Hz or less.)
As set in Pr. 72 "PWM frequency
selection".
Set to the rated slip frequency of
the motor + about 1.0Hz.
This parameter may be set only if
Pr. 278 ≤ Pr. 282.
Generally, set this parameter to
about 50 to 90%. If the setting is
too low, the load is liable to drop
due to gravity at start.
Suppose that the rated inverter
current is 100%.
Generally, set this parameter to
about 0.1 to 0.3s.
Pr. 292 = 7: Set the mechanical
delay time until the brake is loos-
ened.
Pr. 292 = 8: Set the mechanical
delay time until the brake is loos-
ened + about 0.1 to 0.2s.
At this frequency, the brake open-
ing request signal (BOF) is
switched off. Generally, set this
parameter to the Pr. 278 setting +
3 to 4Hz.This parameter may be
set only if Pr. 278 ≤ Pr. 282.
Pr. 292 = 7: Set the mechanical
delay time until the brake is closed
+ 0.1s.
Pr. 292 = 8: Set the mechanical
delay time until the brake is closed
+ about 0.2 to 0.3 seconds.
Brake sequence function is made valid when a setting is "7 or 8".
Droop control is invalid
Set the drooping amount at the
rated torque as a percentage with
respect to the rated motor fre-
quency.
Set the time constant of the pri-
mary delay filter applied to the
torque current.
Parameter overview
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-105
6-109
6-291
6 - 25