Special operation
Output signal
Output terminal assignment during dancer control (PID control) operation
PID signal turns on during dancer control (PID control) or at a stop by PID control (in the status
PID operation being performed inside) (The signal is off during normal operation.)
For the terminal used for PID signal output, assign the function by setting "47 (positive logic) or
147 (negative logic)" in any of Pr. 190 to Pr. 192 "Output terminal function selection".
NOTE
Changing the terminal function using any of Pr. 178 to Pr. 184, Pr. 190 to Pr. 192 may affect
the other functions. Make setting after confirming the function of each terminal.
PID monitor function
The PID control set point and measured value can be output to the operation panel monitor dis-
play and terminal AM.
For each monitor, set the following value in Pr. 52 "DU/PU main display data selection" and
Pr. 158 "AM terminal function selection".
Setting
52
53
54
Tab. 6-108: PID monitor function
Priorities of main speed command
The priorities of the main speed speed command source when the speed command source is
external are as follows.
JOG signal > multi-speed setting signal (RL/RM/RH/REX) > 16 bit digital input (option) > ter-
minal 2
The priorities of the main speed speed command source when "3" is set in Pr. 79.
Multi-speed setting signal (RL/RM/RH/REX) > set frequency (digital setting by PU, operation
panel)
Terminal 4 can not be selected as the main speed speed command even when AU terminal is
turned on.
Even when a remote operation function is selected by setting a value other than "0" in Pr. 59,
compensation of the remote setting frequency to the main speed is ignored (changes to 0).
6 - 288
Monitor Descrip-
Minimum
Increments
tion
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
value
Terminal AM
Remarks
Full Scale
100%
100%
Value cannot be output from the terminal AM.
The PID deviation value of 0% is displayed as
1000.