Extended Parameter Display (Pr. 160) - Mitsubishi Electric FR-D720S SC EC Instruction Manual

Fr-d700 series
Table of Contents

Advertisement

Misoperation prevention and parameter setting restriction
6.16.4

Extended parameter display (Pr. 160)

Parameter 160 allows access to certain parameters via the control panel and the parameter unit
Pr.
Name
No.
Extended function display
160
selection
The above parameter allows its setting to be changed during operation in any operation mode
even if "0" is set in Pr. 77.
Display of simple mode parameters and extended parameters (Pr. 160)
When Pr. 160 = "9999", only the simple mode parameters can be displayed on the operation
panel and parameter unit (FR-PU04/FR-PU07). (Refer to the parameter list Tab. 6-1 for the
simple mode parameters.)
Setting "0" (initial value) to Pr. 160 enables the display of the simple mode parameters and
extended parameters.
NOTES
When RS485 communication is used to read the parameters, all parameters can be read -
regardless of Pr. 160 setting - by setting a value ≠ "2" in Pr. 551 "PU mode operation com-
mand source selection".
Pr. 15 "Jog frequency", Pr. 16 "Jog acceleration/deceleration time", and Pr. 991 "PU contrast
adjustment" are displayed as simple mode parameter when the parameter unit (FR-PU04/
FR-PU07) is fitted.
6 - 168
Initial
Setting
Description
Setting
Range
Displays only the simple mode parame-
9999
ters.
0
Displays simple mode and extended
0
parameters.
Parameter
Refer to
Parameters referred to
Section
Jog frequency
15
6.5.2
Jog acceleration/
16
6.5.2
deceleration time
PU mode operation
551
6.17.3
command source
selection

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-d740 sc ec

Table of Contents