Mitsubishi Electric FR-E700 Instruction Manual page 203

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
JOG operation from PU
Selects Jog operation mode from the operation panel and PU (FR-PU04/FR-PU07). Operation
is performed only while the start button is pressed.
Confirmation of the RUN indication and operation
mode indication.
The monitor mode must have been selected.
The inverter must be at a stop.
Press the PU/EXT key to choose the
PU JOG operation mode.
Press the RUN key.
The motor rotates while the key is pressed.
It rotates at 5Hz (initial value of Pr. 15).
Release the RUN key to stop the motor.
When changing the frequency of PU JOG operation:
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until Pr. 15 "JOG frequency"
appears.
Press the SET key to show the currently set value
(5Hz).
Turn the digital dial to set the value to "10.00"
(10.00Hz).
Press the SET key to set.
Perform the operations in steps
The motor rotates at 10Hz.
Fig. 6-24: JOG operation performed from PU
FR-E700 EC
Inverter
Power
supply
Operation panel
Operation
Frequency setting by external terminals
Fig. 6-23:
Connection example for jog operation
performed from PU
Motor
Hold down
Release
to
I001790E
Display
Stop
"PRM" indication is lit.
The parameter number read previously
appears.
Flicker ... Parameter setting complete!
I001791E
6 - 63