Parameter
Parameter
Func-
Name
tion
Motor constant (X)
94
Auto tuning setting/
96
status
Torque current
859
89
Refer to Pr. 81
90
Refer to Pr. 82 to 84
94
96
Refer to Pr. 82 to 84
Tab. 6-1:
Parameter overview (15)
FR-E700 EC
Incre-
Initial
Setting
ments
value
range
0–100% *
0.1% *
9999
9999
0
1
1
0
11
21
0–500A *
0.01A *
9999
9999
Description
Tuning data (The value measured
by offline auto tuning is automati-
cally set.)
* The range differs according to
the Pr. 71 setting.
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Offline auto tuning is not per-
formed
For advanced magnetic flux vector
control
Offline auto tuning is performed
without motor running (all motor
constants)
For general-purpose magnetic flux
vector control
Offline auto tuning is performed
without motor running (motor
constant (R1) only)
Offline auto tuning for V/F control
(automatic restart after instantane-
ous power failure (with frequency
search))
Tuning data (The value measured
by offline auto tuning is automati-
cally set.)
* The range differs according to
the Pr. 71 setting.
Use the Mitsubishi motor (SF-JR,
SF-HRCA) constants
Parameter overview
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-88
6 - 15