Mitsubishi Electric FR-E700 Instruction Manual page 169

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
Parameter
Func-
Name
tion
888
Free parameter 1
889
Free parameter 2
C1
AM terminal calibration
(901)
AM 0V adjustment
645
C2
(902)
Refer to Pr. 125 and Pr. 126
C7
(905)
C22
(922)
Parameter for manufacturer setting. Do not set.
C25
(923)
990
PU buzzer control
PU contrast
991
adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Fault history clear
Pr.CH
Initial value change list
Tab. 6-1:
Parameter overview (29)
NOTE
The parameter number in parentheses is the one for use with the parameter unit (FR-PU04/
FR-PU07).
FR-E700 EC
Incre-
Initial
Setting
ments
value
range
1
9999
0–9999
1
9999
0–9999
1
1000
970–1200
0
1
1
1
1
58
0–63
1
0
0/1
1
0
0/1
1
0
0/1
1
0
0
Description
Parameters you can use for your
own purposes.
Used for maintenance, manage-
ment, etc. by setting a unique
number to each inverter when
multiple inverters are used.
Data is held even if the inverter
power is turned off.
Calibrate the scale of the analog
meter connected to terminal AM.
Calibrates the scale of the meter
when analog output is 0.
Without buzzer
With buzzer
Contrast adjustment of the LCD of
the parameter unit (FR-PU04) can
be performed.
0 (light) → 63 (dark)
Setting "1" returns all parameters except calibration param-
eters to the initial values.
Setting "1" returns all parameters to the initial values.
Setting "1" will clear eight past alarms.
Displays the parameters changed from the initial value.
Parameter overview
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-305
6-148
6-309
6-309
4-16
4-16
7-18
4-17
6 - 29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740