Mitsubishi Electric FR-E700 Instruction Manual page 116

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Simple mode parameter list
Monitor display during auto tuning
Monitor is displayed on the operation panel and parameter unit (FR-PU04/FR-PU07) during tun-
ing as below.
Parameter 96
Setting
Tuning in
progress
Normal end
Error end
(when inverter
protective func-
tion operation is
activated)
Tab. 5-4: Monitor display
NOTE
The set frequency monitor displayed during the offline auto tuning is 0Hz.
Reference: Offline auto tuning time (when the initial value is set)
Offline Auto Tuning Setting
Tune all motor constants (Pr. 96 = 1)
Tune motor constants (R1) only (Pr. 96 = 11)
Tab. 5-5: Offline auto tuning time (when the initial value is set)
Return to the normal operation mode
When offline auto tuning ends, press the STOP/RESET key of the operation panel during PU
operation.
For external operation, turn off the start signal (STF signal or STR signal) once.
This operation resets the offline auto tuning and the PU's monitor display returns to the normal
indication. (Without this operation, next operation cannot be started.)
NOTE
Do not change the Pr. 96 setting after completion of tuning (3 or 13). If the Pr. 96 setting is
changed, tuning data is made invalid. If the Pr. 96 setting is changed, tuning must be per-
formed again.
5 - 18
Parameter Unit
(FR-PU04/FR-PU07) Display
1
11
READ:List
READ:List
1
11
STOP
PU
STOP
PU
TUNE
TUNE
2
12
STF
FWD
PU
STF
FWD PU
TUNE
TUNE
3
13
COMPETION
COMPLETION
STOP PU
STF
STOP PU
STF
TUNE
9
ERROR
STF
STOP PU
Operation Panel Indication
1
Flickering
Time
Approximately 25 to 75s
(Tuning time differs according to the inverter capacity and
motor type.)
Approximately 9s
Basic settings
11
Flickering

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740Fr-e700 seriesFr-e720s ecFr-e740 ec

Table of Contents