Misoperation prevention and parameter
setting restriction

3.16.3 Reverse rotation prevention selection (Pr.78)

This function can prevent reverse rotation fault resulting from the incorrect input of the start signal.
Pr. 77
page 139
Pr. 79
Parameter
page 142
Number
Reverse rotation prevention
78
selection
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 140.)
⋅ Set this parameter when you want to limit the motor rotation to only one direction.
⋅ This parameter is valid for all of the reverse rotation and forward rotation keys of the operation panel (FR-DU07),
parameter unit (FR-PU04), signals (STF, STR signals) via external terminals, and the forward and reverse
rotation commands through communication.
♦ Parameters referred to ♦
Pr. 79 Operation mode selection

3.16.4 Display of applied parameters and user group function (Pr.160, Pr.172 to Pr.174)

Parameter which can be read from the operation panel and parameter unit can be restricted.
Pr.159
In the initial setting, only the simple mode parameters are displayed.
page 192
Pr.161
page 217
Parameter
Pr.171
Number
page 100
Pr.178
page 85
160
User group read selection
User group registered display/
172
*1
batch clear
173
User group registration
*1, 2
174
User group clear
*1, 2
*1
They can be set when Pr. 160 User group read selection = "0".
*2
The values read from Pr. 173 and Pr. 174 are always "9999".
(1) Display of simple mode parameters and extended parameters (Pr.160)
⋅ When Pr. 160 = "9999" (initial value), only the simple mode parameters can be displayed on the operation panel (FR-
DU07) and parameter unit (FR-PU04).(Refer to the parameter list, pages 38 to 50, for the simple mode parameters.)
⋅ Setting "0" to Pr. 160 enables the display of the simple mode parameters and extended parameters.
REMARKS
⋅ When a plug-in option is fitted to the inverter, the option parameters can also be read.
⋅ When reading the parameters using the communication option, all parameters (simple mode, extended mode, parameters
for options) can be read regardless of the Pr. 160 setting.
⋅ When reading the parameters using the RS-485
terminal, all parameters can be read reagrdless of the Pr.
160 setting by setting Pr.550 NET mode operation command
source selection and Pr. 551 PU mode operation command
source selection.
⋅ Pr. 15 Jog frequency, Pr. 16 Jog acceleration/deceleration time, Pr. 145 PU display language selection, Pr. 991 PU contrast adjustment
are displayed as simple mode parameters when the parameter unit (FR-PU04) is mounted.
140
Name
Initial Value
Refer to page 142
Name
Initial Value
9999
9999
9999
Setting Range
0
0
1
2
Setting Range
9999
0
1
(0 to 16)
0
9999
0 to 999, 9999
0 to 999, 9999
Pr.551
Pr.550
1 (RS-485)
0(OP)
2
1(RS-485)
(PU)
9999
(initial
(auto-detect)
value)
(initial value)
*
OP indicates a communication option
Description
Both forward and reverse rotations
allowed
Reverse rotation disabled
Forward rotation disallowed
Description
Only the simple mode parameters
can be displayed.
The simple mode and extended
parameters can be displayed
Only parameters registered in the
user group can be displayed.
Displays the number of cases
registered as a user group (Read only)
Batch clear the user group
registration
Set the parameter numbers to be
registered to the user group.
Set the parameter numbers to be
cleared from the user group.
Pr.160 Valid/Invalid
Valid
Valid
Invalid (all readable)
With OP: valid
Without OP: invalid
(all readable)