Wiring
3.4.1

Control circuit terminals

Terminal screw size
Terminals A, B and C: M3
Other than the above: M2
Fig. 3-6: Terminal layout
Wiring method
Remove about 6mm of the cable insulation. Wire the stripped cable after twisting it to prevent
it from becoming loose. In addition, do
Loosen the terminal screw and insert the cable into the terminal.
Tab. 3-12: Connection to the terminals
b
CAUTION:
Undertightening can cause cable disconnection or malfunction. Overtightening can
cause a short circuit or malfunction due to damage to the screw or unit.
FR-E700 EC
X
X = 6mm (Terminal A, B and C)
5mm (Other than the above)
Item
Screw size
Tightening torque
Cable size
Screwdriver
AM
.
not solder it
Fig. 3-7:
Preparation of the cable
Terminals A, B and C
M3
0.5Nm–0.6Nm
0.3mm²–0.75mm²
Flat blade screw driver
Edge thickness: 0,4mm × 2,5mm
Control circuit specifications
Other terminals
M2
0.22 Nm–0.25 Nm
0.3 mm²–0.5 mm²
I001917E
I001326E
3 - 17