Mitsubishi Electric FR-E700 Instruction Manual page 146

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter overview
Parameter
Func-
Name
tion
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
RUN key rotation direc-
40
tion selection
Up-to-frequency
41
sensitivity (SU output)
Output frequency
42
detection (FU output)
Output frequency
43
detection for reverse
rotation
44
Refer to Pr. 7 and Pr. 8
45
46
Refer to Pr. 0
47
Refer to Pr. 3
48
Refer to Pr. 22
51
Refer to Pr. 9
Tab. 6-1:
Parameter overview (6)
6 - 6
Incre-
Initial
Setting
ments
value
range
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0–400Hz/
0.01Hz
9999
9999
0
0.001
0
0.01–9998
0
1
0
1
0.1%
10%
0–100%
0.01Hz
6Hz
0–400Hz
0–400Hz
0.01Hz
9999
9999
Description
1A to 1B, 2A to 2B, 3A to 3B are
frequency jumps
9999: Function invalid
Frequency display, setting
Set the machine speed at 60Hz.
Forward rotation
Reverse rotation
Set the level where the SU signal
turns on.
Set the frequency where the FU
signal turns on.
Set the frequency where the FU
signal turns on in reverse rotation.
Same as Pr. 42 setting
Parameter
All
Para-
Para-
Para-
meter
meter
meter
copy
clear
clear
Refer
to
page
✔: enabled
—: disabled
6-52
6-136
6-306
6-129

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740Fr-e700 seriesFr-e720s ecFr-e740 ec

Table of Contents