Adjust the output torque (current) of the motor
Adjust the motor speed fluctuation at load fluctuation
The motor speed fluctuation at load fluctuation can be adjusted using Pr. 89. (It is useful when
the speed command does not match the motor speed after the FR-E500 series inverter is re-
placed with the FR-E700 series inverter, etc.)
6 - 38
Speed
Fig. 6-3:
Adjustment of speed fluctuations
Parameter
I001544E