Parameter
6.3.3
General-purpose magnetic flux vector control
(Pr. 71, Pr. 80, Pr. 81, Pr. 800)
General-purpose magnetic flux vector control is the same function as the FR-E500 series. Se-
lect this control when the same operation characteristic is necessary. For other cases, select ad-
vanced magnetic flux vector control.
Pr.
Initial
Name
No.
Value
71
Applied motor
80
Motor capacity
9999
Number of motor
81
9999
poles
Control method
800
selection
The above parameters can be set when Pr. 160 "User group read selection" = 0.
Set a value other than "9999" in Pr. 80 and Pr. 81.
If the following conditions are not satisfied, select V/f control since malfunction such as insuf-
ficient torque and uneven rotation may occur.
● The motor capacity should be equal to or one rank lower than the inverter capacity.
● Motor to be used is any of Mitsubishi standard motor, high efficiency motor (SF-JR, SF-HR
0.2kW or more) or Mitsubishi constant-torque motor (SF-JRCA, SF-HRCA four-pole 0.4kW
to 15kW). When using a motor other than the above (other manufacturer's motor), perform
offline auto tuning without fail.
● Single-motor operation (one motor run by one inverter) should be performed.
● The wiring length from inverter to motor should be within 30m. (Perform offline auto tuning
in the state where wiring work is performed when the wiring length exceeds 30m.)
● Permissible wiring length between inverter and motor differs according to the inverter
capacity and setting value of Pr. 72 "PWM frequency selection" (carrier frequency). (Refer
to page 3-12).
FR-E700 EC
Setting Range
Description
0/1/3–6/13–16/
By selecting a standard motor or constant
0
23/24/40/43/44/
torque motor, thermal characteristic and
50/53/54
motor constants of each motor are set.
0.1–15kW
Applied motor capacity.
9999
V/f control
2/4/6/8/10
Number of motor poles.
9999
V/f control
20
Advanced magnetic flux vector control
20
General-purpose magnetic flux vector
30
control
Adjust the output torque (current) of the motor
GP MFVC
GP MFVC
GP MFVC
Refer to
Parameters referred to
Section
3
Base frequency
6.5.1
19
Base frequency
6.5.1
71
Applied motor
6.8.2
77
Parameter write
6.17.2
selection
6 - 39