Misoperation prevention and parameter setting restriction
Restarting method when stop was made by pressing the STOP key from the PU during
external operation ("PS" is displayed)
Operation panel
After the motor has decelerated to a stop, turn off the STF or STR signal.
Press the PU/EXT key to change to the PU operation mode. The PU indication is lit. The
message "PS" is canceled.
Press the PU/EXT key to change to the external operation mode. The EXT indication is lit.
Turn on the STF or STR signal.
Operation panel
Fig. 6-98: Stop during external operation
Parameter unit (FR-PU04/FR-PU07)
After completion of deceleration to a stop, switch off the STF or STR signal.
Press the EXT key. The message "PS" is canceled.
Switch on the STF or STR signal.
The motor can be restarted by making a reset using a power supply reset or RES signal.
NOTE
If Pr. 250 "Stop selection" is set to other than "9999" to select coasting to a stop, the motor
will not be coasted to a stop but decelerated to a stop by the PU stop function during exter-
nal operation.
6 - 190
Speed
STF (EIN)
STR (AUS)
PU key
STOP key
Parameter
Time
I000027C