Parameter
Operation mode selection flow
In the following flowchart, select the basic parameter setting and terminal connection related to
the operation mode:
START
Where is the start command
source?
From external (STF/STR terminal)
Where is the
frequency set?
From external (Terminal 2, 4,
JOG, multi-speed, etc.)
From PU
From communication (PU connector/communication option)
PU connector or
communication option?
PU connector
(RS-485 communication)
Communication option
From PU
Where is the
frequency set?
From external (Terminal 2, 4,
JOG, multi-speed, etc.)
From PU
From communication
(PU connector/communication
option)
From communication (PU connector/communication option)
PU connector or
communication option?
PU connector
(RS-485 communication)
Where is the
frequency set?
From external (Terminal 2, 4, JOG, multi-speed, etc.)
From the operation panel
From communication (PU connector)
Communication option
Where is the
frequency set?
From external (Terminal 2, 4, JOG, multi-speed, etc.)
From the operation panel
From communication (communication option)
FR-E700 EC
Connection
STF (forward rotation)/
STR (reverse rotation)
(Refer to page 6-114)
Terminal 2, 4-5 (analog), RL, RM,
RH, JOG, etc.
STF (forward rotation)/
STR (reverse rotation)
(Refer to page 6-114)
STF (forward rotation)/
STR(reverse rotation)
(Refer to page 6-114)
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Terminal 2, 4-5 (analog), RL, RM,
RH, JOG, etc.
Disabled
Terminal 2, 4-5 (analog), RL, RM,
RH, JOG, etc.
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Terminal 2, 4-5 (analog), RL, RM,
RH, JOG-PC, etc.
Connection of communication option
(Refer to the corresponding commu-
nication option instruction manual)
Selection of operation mode and operation location
Parameter setting
Pr. 79 = 3
(External/PU combined
operation 1)
Pr. 338 = 1
Pr. 340 = 1
Pr. 338 = 1
Pr. 340 = 1
Pr. 79 = 4
(External/PU combined
operation 2)
Pr. 79 = 1
(Fixed to PU operation)
Pr. 339 = 1
Pr. 340 = 1
Disabled
Pr. 340 = 1
Pr. 339 = 1
Pr. 340 = 1
Disabled
Pr. 340 = 1
Operation
Frequency setting signal ON
STF(STR) ON
Digital dial
Communication frequency setting
command sending
STF(STR) ON
Communication frequency setting
command sending
STF(STR) ON
Frequency setting terminal ON
RUN/FWD/REV key ON
Digital dial
Frequency setting terminal ON
Communication start command
sending
Communication frequency setting
command sending
Communication start command
sending
Frequency setting terminal ON
Communication start command
sending
Communication frequency setting
command sending
Communication start command
sending
6 - 201