Check and clear of the fault history

7.5
Check and clear of the fault history
Check for the fault history
Fig. 7-5: Displaying the fault list and the status values for the time of the fault
The cumulative energization time and actual operation time are accumulated from 0 to 65535
hours, then cleared, and accumulated again from 0. When the operation panel is used, the
time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is
added up from 0.
7 - 18
Monitor/frequency setting
Operation panel is used for
operation
Faults history
Procedure for displaying the faults history and the status values for the time of the fault
Eight past faults can be displayed with the digital dial.
(The last fault in the list is identified by a dot after the E: "E.")
Flickering
Flickering
Flickering
Parameter setting
Parameter setting change
When no alarm exists
is displayed.
Output frequency
Flickering
Energizing time
Flickering
Fault history number
(The number of past faults is displayed.)
Press
the
digital dial.
Press
the
digital dial.
Press
the
digital dial.
Troubleshooting
Output current
Flickering
Output voltage
Flickering
I001857E