Mitsubishi Electric FR-E700 Instruction Manual page 469

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Troubleshooting
Clearing procedure
The fault history can be cleared by setting "1" in Er.CL "Faults history clear". (The fault history
is not cleared when "1" is set in Pr. 77 "Parameter write selection".)
Screen at powering on
The monitor display appears.
Press the MODE key to choose the parameter
setting mode.
Turn the digital dial until Er.CL appears.
Press the SET key to show the currently set value.
The initial value "0" appears.
Turn the digital dial to change it to the set value "1".
Press the SET key to set.
By turning the digital dial, you can read another parameter.
Press the SET key to show the setting again.
Press the SET key twice to show the next parameter.
Fig. 7-6: Clearing the fault history
FR-E700 EC
Operation
Check and clear of the fault history
Display
The parameter number
read previously
appears.
Flicker ... Fault history clear complete!
I001858E
7 - 19