Mitsubishi Electric FR-E700 Instruction Manual page 202

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Frequency setting by external terminals
Pr. 20
JOG
STF
STR
Screen at powering on
Confirm that the external operation mode is
selected. (EXT indication is lit)
If not displayed, press the PU/EXT key to change
to the external operation mode If the operation
mode still does not change, set Pr. 79 to change
to the external operation mode.
Turn the JOG switch on.
Turn the start switch STF or STR on.
The motor rotates while the start switch is ON.
It rotates at 5Hz (initial value of Pr. 15).
Turn the start switch STF or STR off.
Fig. 6-22: Jog operation in the external operation mode
6 - 62
Hz
Forward rotation
Pr. 16
Reverse
rotation
ON
ON
ON
Operation
Fig. 6-21:
Jog operation signal timing chart
Jog
frequency
Pr. 15
t
t
t
t
ON
Forward
rotation
ON
Reverse
rotation
Forward
rotation
OFF
Display
JOG
Rotates while ON.
Reverse
rotation
Parameter
I001324C
Stop
I001789E