Mitsubishi Electric FR-E700 Instruction Manual page 237

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Parameter
Pr.
82
90
91
92
93
94
859
Tab. 6-22: Setting of parameter 82, 90 to 94 and 859
Refer to the following table and set Pr. 83 and Pr. 84.
Pr.
83
84
Tab. 6-23: Setting of parameter 83 and 84
NOTE
When "9999" is set in Pr. 82, Pr. 90 to Pr. 94, Pr. 859, Mitsubishi motor (SF-JR, SF-HR, SF-
JRCA, SF-HRCA) constants are used.
FR-E700 EC
Name
Motor excitation current
(no load current)
Motor constant R1
Motor constant R2
Motor constant L1
Motor constant L2
Motor constant X
Torque current
Name
Motor rated voltage
Rated Motor Frequency
Setting Range
Setting Inrements
0–500A, 9999
0–50Ω, 9999
0–50Ω, 9999
0–1000mH, 9999
0–1000mH, 9999
0–100%, 9999
0–500A, 9999
Setting Range
0–1000V
10–120Hz
Selection and protection of a motor
Initial Value
0.01A
9999
0.001Ω
9999
0.001Ω
9999
0.1mH
9999
0.1mH
9999
0.1%
9999
0.01A
9999
Setting Inrements
Initial Value
0.1V
0.01Hz
400V
50Hz
6 - 97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740Fr-e700 seriesFr-e720s ecFr-e740 ec

Table of Contents