Mitsubishi Electric FR-E700 Instruction Manual page 384

Frequency inverter
Hide thumbs Also See for FR-E700:
Table of Contents

Advertisement

Communication operation and setting
No. Item
Set frequency (RAM)
Set frequency (E²PROM)
Set frequency (RAM)
5
Set frequency
(RAM, E²PROM)
6
Inverter reset
7
Alarm definition all clear
8
All parameter clear
Tab. 6-73: Setting of the instruction codes and data (2)
6 - 244
Read/
Instruction
Data Description
Code
write
H6D
Read set frequency/speed from RAM or
E²PROM.
H0000 to HFFFF: Set frequency in 0.01Hz
increments
Speed increments 0.001 (when Pr. 37 =
Read
0.01 to 9998)
H6E
When "0.01 to 9998" is set in Pr. 37 and
"01" in instruction code HFF, the incre-
ments change to 0.001 and the data format
is E2.
HED
Write set frequency/speed to RAM or
E²PROM.
H0000 to H9C40 (0 to 400.00Hz):
Frequency increments 0.01Hz
Speed increments 0.001 (when Pr. 37 =
0.01 to 9998)
When "0.01 to 9998" is set in Pr. 37 and
Write
HEE
"01" in instruction code HFF, the incre-
ments change to 0.001 and the data format
is A2.
To change the set frequency consecutively,
write data to the inverter RAM. (instruction
code: HED)
H9696: Resets the inverter.
As the inverter is reset at start of communi-
cation by the computer, the inverter cannot
send reply data back to the computer.
Write
HFD
H9666: Resets the inverter.
When data is sent normally, ACK is
returned to the computer and then the
inverter is reset.
H9696: Alarm history batch clear
Write
HF4
All parameters return to the initial values.
Whether to clear communication parame-
ters or not can be selected according to
data. (✔: Clear, —: Not clear) Refer to Tab.
6-1 for parameter clear, all clear, and com-
munication parameters.
Write
HFC
When all parameter clear is executed for
H9696 or H9966, communication-related
parameter settings also return to the initial
values. When resuming operation, set
these parameters again.
Executing clear will clear the instruction
code HEC, HF3, and HFF settings.
Communication-
Clear Type
Data
parameter
H9696
Parameter
clear
H5A5A
H9966
All parameter
clear
H55AA
Note that when using a three-phase
power input specification model, Pr. 345
and Pr. 346 are set back to initial values.
Parameter
Number
of Data
Digits
(Format)
4
(B, E/D)
6
(B, E,
E2'/D)
4
(A, C/D)
6
(A, A2,
C/D)
4
(A, C/D)
4
(A, D)
4
(A, C/D)
4
(A, C/D)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e720sFr-e740Fr-e700 seriesFr-e720s ecFr-e740 ec