Exception Error; Communication Error - Xerox DocuColor 1632 Service Manual

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

116-324 Exception Error

CPU exceptional error.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to Service Call Procedures.
Replace the ESS PWB
(PL
13.1).
Prelaunch Training/Review
DC1632/2240

116-325 Communication Error

+24 VDC enabled Communications failure.
Procedure
+24 VDC power is failed. Status Code 102-319 is displayed after 116-325 is displayed.
Y
N
Preliminary information not available.
+24V LVPS is failed. Perform following:
ï
Remove Rear Cover
(REP
14.2).
ï
Remove cover from +24V LVPS (PL 9.1).
ï
Disconnect P502 on +24V LVPS
Check that power is switched off. Measure resistance of fuse on +24V LVPS. Resistance is 1
ohm or less.
Y
N
Replace +24V LVPS (PL 9.1).
Switch on the power. Measure the AC voltage between the white and black wires in P2 on the
+24 VDC. 110 or 220 VAC is measured.
Y
N
Go to the AC Power RAP.
Connect the black meter lead to DC COM or frame. Measure DC voltage at P505 on the +24 V
LVPS
(Figure
1). Voltages are measured as shown.
Y
N
There is a problem with the +24 VDC enable circuit. Go to the +24 VDC Enable RAP.
Measure the DC voltage at P502 on the +24V LVPS
shown.
Y
N
Replace the 24V LVPS (PL 9.1).
There is a short circuit in +24 VDC distribution. Go to the +24 VDC Short Circuit RAP.
+24 VDC RET
Vio (all on top)
+24 VDC
Orn (all)
Figure 1 P502, P505 on +24V LVPS
6/02
2-371
(Figure
1).
(Figure
1). Voltages are measured as
+24V, 0V, +3.5V, +5V
Status Indicator RAPs
116-324, 116-325

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 2240

Table of Contents