9-684 ADC Shutter

The machine logic detected an ADC Shutter operation failure.
Procedure
BSD 9.16, 9.31D
Enter
dC330
[009-078]. The ADC Shutter Solenoid energized.
Y
N
There is +24VDC from P/J 536-A7 on the I/F PWB to GND.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
the problem continues, replace the ADC Sensor
Enter
dC330
[009-078]. There is 0VDC from P/J536-A8 on the I/F PWB to GND.
A
Prelaunch Training/Review
DC1632/2240
A
(PL
9.1). If
(PL
1.3).
After checking that no failures are detected during normal operation, go to call closeout.
Figure 1 The ADC Sensor
6/02
2-161
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
the problem continues, replace the MCU PWB
replace the ADC Sensor
(PL
1.3).
Enter
dC330
[009-079]. The voltage from P/J 536-A6 on the I/F PWB to GND changed to
0VDC momentarily.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB
the problem continues, replace the MCU PWB
replace the ADC Sensor (PL 1.3).
Check the wires and connectors. If the check is OK, replace the ADC Sensor (PL 1.3).
(PL
9.1). If
(PL
13.1). If the problem continues,
(PL
9.1). If
(PL
13.1). If the problem continues,
Status Indicator RAPs