Xerox DocuColor 1632 Service Manual page 806

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

Chain-Link
Name
760-029
OLRC implementation SW
760-030
Y-OLRC Start Temp
760-031
M-OLRC Start Temp
760-032
K-OLRC Start Temp
760-035
Aok (for Diag Regi Con)
760-036
Aok (for normal Regi Con)
760-037
LEDset-IN-A
760-038
LEDset-IN-B
760-043
LEDset-OUT-A
760-044
LEDset-OUT-B
760-049
Y-XBI
760-050
M-XBI
760-051
C-XBI
760-052
K-XBI
760-053
Y-OLXSO
760-054
M-OLXSO
760-055
C-OLXSO
760-056
K-OLXSO
760-057
Y-OLXBI
760-058
M-OLXBI
760-059
O-OLXBI
General Procedures and Information
Table 15 Chain 760
Default
Range
Description
1
0~1
0 = Does not perform OLRegi Control 1 = Performs OLRegi Control
30
10~100
Threshold of Yellow Open Loop Regi Control Implementation Temperature difference. Value on the left is 10
times of the Temperature. (0.1 Degree Celsius interval)
30
10~100
Threshold of Magenta Open Loop Regi Control Implementation Temperature difference. Value on the left is 10
times of the Temperature. (0.1 Degree Celsius interval)
30
10~100
Threshold of Black Open Loop Regi Control Implementation Temperature difference. Value on the left is 10
times of the Temperature. (0.1 Degree Celsius interval)
20
1~24
Threshold of No. of valid Blocks of fine adjustment pattern at Diag Regi Control (DC685). NG occurs if the value
is out corrected below the Threshold.
8
1~12
Threshold of No. of valid Blocks of fine adjustment pattern at Normal Regi Control. NG occurs if the value is out
corrected below the Threshold.
2
0~2
MOB LED ON/OFF and Light Quantity Step at IN side. 0 = Off 1 = Low 2 = High
2
0~2
MOB LED ON/OFF and Light Quantity Step at IN side.0 = Off 1 = Low 2 = High
2
0~2
MOB LED ON/OFF and Light Quantity Step at OUT side. 0 = Off 1 = Low 2 = High
2
0~2
MOB LED ON/OFF and Light Quantity Step at OUT side 0 = Off 1 = Low 2 = High
0
0~3
Adjusts the Fast Scan direction write start position by Switching the Video Lock position phase from SOS Sig-
nal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
0
0~3
Adjusts the Fast Scan direction write start position by Switching the Video Lock position phase from SOS Sig-
nal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
0
0~3
Adjusts the Fast Scan direction write start position by Switching the Video Lock position phase from SOS Sig-
nal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
0
0~3
Adjusts the Fast Scan direction write start position by Switching the Video Lock position phase from SOS Sig-
nal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
10
0~20
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by the No. of
Video Locks from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correction
Resolution Ability = 1 Pixel unit)
10
0~20
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by the No. of
Video Locks from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correction
Resolution Ability = 1 Pixel unit)
10
0~20
The normal Regi Control cycle separately adjusts the Fast Scan direction write start position by the No. of Video
Locks from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correction Resolution
Ability = 1 Pixel unit)
10
0~20
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by the No. of
Video Locks from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correction
Resolution Ability = 1 Pixel unit)
0
0~3
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by replacing the
Video Locks phase from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correc-
tion Resolution Ability = 1 Pixel unit)
0
0~3
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by replacing the
Video Locks phase from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correc-
tion Resolution Ability = 1 Pixel unit)
0
0~3
The normal Regi Control cycle, separately adjusts the Fast Scan direction write start position by replacing the
Video Locks phase from SOS signal in an Open Loop, from the temperature detection result. (4 Colors/Correc-
tion Resolution Ability = 1 Pixel unit)
6/02
6-42
Prelaunch Training/Review
DC1632/2240

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 2240

Table of Contents