10-352 Main Heater Warm Up
The temperature did not reach the READY temperature within the specified time.
Procedure
Turn off the power, remove the Fuser Assembly. and allow it to cool down.
Measure the resistance between P/J600-4 and P/J600-6 on the Fuser Assembly.
The resistance is between 30 and 190 K Ohmís.
Y
N
Check the Front Thermistor for an open circuit and poor contact. If the check is OK,
replace the Sensor Assembly (PL 7.2).
Measure the resistance between P/J600-3 and P/J600-12 on the Fuser Assembly. The resis-
tance is 20 Ohmís or less.
Y
N
Replace the Fuser Assembly (PL 7.1).
Reinstall the Fuser Assembly, turn the power on, enter
display is between 678 and 699.
Y
N
Turn the power off. Check for an open or poor connection between P/J404-12 on the MCU
PWB and P/J600-6 on the Fuser Assembly. If the check is OK, replace the MCU PWB (PL
13.1).
There is Line Voltage measured at FS41 on the AC Drive PWB (PL 9.2).
Y
N
There is +5VDC measured at P/J590-5 on the AC Drive PWB (PL 9.2).
Y
N
Check the wires and connectors. If the check is OK, replace the MCU PWB (PL
13.1).
There is +24VDC measured at P/J590-1 on the AC Drive PWB (PL 9.2).
Y
N
Check the wires and connectors. If the check is OK, replace the MCU PWB (PL
13.1).
Replace the AC Drive PWB (PL 9.2).
Check the wires and connectors. If the check is OK, replace the Fuser Assembly (PL 7.1).
Prelaunch Training/Review
DC1632/2240
dC140
[010-100] and press Start. The
6/02
2-185
Figure 1 Fuser Front and Rear Thermistor CD
Status Indicator RAPs
10-352