REP 9.8 Plate Assembly

Parts List on
PL 4.2
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Remove Front Cover
(REP
14.7).
2.
Remove Drum Cartridges.
3.
Remove Waste Cartridge
(REP
9.4).
4.
Remove Waste Cartridge Cover
(REP
5.
Remove Fuser Front Cover
(REP
14.8).
6.
Release and move Xerographic Release Lever half way down.
7.
Remove Dispenser Assembly Cover
8.
Remove all Dispenser Assemblies
Note position of harnesses. Correct harness routing is required for assembly.
NOTE: In next step, do not remove sensor.
9.
Remove housing for Waste Cartridge Full Sensor
Prelaunch Training/Review
DC1632/2240
WARNING
9.3).
(REP
9.6).
(REP
9.7).
CAUTION
(REP
9.5).
10. Disconnect Developer Housing Plugs, 4 large and 4 small (small not shown).
Position wires straight out from machine. Wires remain stationary while removing Plate
Assembly
(Figure
1).
Developer
Housing Plugs
(4 Large)
Figure 1 Disconnecting Developer Housing Plugs