REP 12.10 Rail
Parts List on
PL 17.9
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Remove the following:
a.
Front Cover
(PL
17.5)
b.
Rear Cover
(PL
17.5)
2.
Remove Harness from Stapler
(Figure
4
Disconnect
Harness
from Motor
and remove
Harness
from Guide
Figure 1 Removing Harness from Stapler
Prelaunch Training/Review
DC1632/2240
WARNING
1).
1
Disconnect Sta-
pler P/Jís (2)
2
Disconnect
Sensor
3
Disconnect
Harness Clip
from Frame
3.
Remove Stapler Assembly
(Figure
Figure 2 Removing Stapler Assembly
6/02
4-115
2).
Remove
Screws (2),
Ground Wire
(1) and Stapler
Repairs and Adjustments