REP 5.19 Platen Belt
Parts List on
PL 20.10
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
NOTE: After replacing Platen Belt, reset HFSI counter. Enter DC135 HFSI Counters Diag.
Screen (NVM 005-805).
Switch off the power and disconnect power cord.
1.
Remove Front Cover
(PL
20.1).
2.
Remove Document Transport
(REP
3.
Remove Platen Belt (Figure 2).
a.
Loosen screws (2).
b.
Move shaft support in direction of arrow.
c.
Remove Platen Belt.
Figure 1 Removing Platen Belt
Repairs and Adjustments
REP 5.19
WARNING
WARNING
5.17).
Replacement
NOTE: Lock shaft support by matching hole with frame's detent (Figure 3).
Figure 2 Lock shaft support
6/02