REP 5.10 Set Gate Solenoid Assembly
Parts List on
PL 20.5
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Open Top Cover.
2.
Remove following:
a.
Front Cover (PL 20.1).
b.
Entrance Tray (PL 20.1).
3.
Remove Lower Chute Assembly
(REP
4.
Remove Set Gate Solenoid Assembly (Figure 1).
1
Make note of pin
engagement
2
Disconnect
3
Release clamp
and remove wire
Figure 1 Removing Set Gate Solenoid Assembly
Prelaunch Training/Review
DC1632/2240
WARNING
5.8).
4
Loosen screws
(2) and remove
solenoid
Replacement
1.
Engage pin with slot (Figure 2).
Figure 2 Engaging Pin with Slot
6/02
4-27
Slot
Pin
Repairs and Adjustments
REP 5.10