102-200 Receive Buffer Overflow
The data received from the Controller exceeded the buffer amount of the destination in the
Panel.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the software.
If the problem continues, replace the ESS PWB
Prelaunch Training/Review
DC1632/2240
(PL
13.1)
102-201 Send Buffer Overflow
The data to be sent from the Panel exceeded the buffer amount of the destination in the Panel.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the software.
If the problem continues, replace the ESS PWB
6/02
2-303
(PL
13.1)
Status Indicator RAPs