12-281 Set Clamp
The Set Clamp Home Sensor does not turn on within 200ms after the Set Clamp has started
operation.
Procedure
Enter dC330 [012-211] and press Start. Rotate the Actuator and turn the Set Clamp Home
Sensor on/off. The display changes.
Y
N
Check the Set Clamp Home Sensor using the Generic Transmissive Sensor RAP.
Enter dC330 [012-040] and press Start. The Set Clamp Solenoid energized.
Y
N
Check the Set Clamp Solenoid using the Generic Solenoid/Clutch Open RAP.
Enter [12-034] and press Start to energize Eject Clamp up or [12-032] to lower the Eject
Clamp.
Enter dC330 [012-041] and press Start. Has the Set Clamp rotated.
Y
N
Enter dC330 [012-030] and press Start. The Eject Motor energized.
Y
N
+24 VDC is measured between the Finisher PWB p/j (+) and Finisher PWB
Chassis (-).
Y
N
Replace the Finisher PWB
Check the wire between the Finisher PWB p/j and the Eject Motor p/j for an open cir-
cuit or poor contact.
If no problems are found, replace the Eject Motor
If the problem continues, replace the Finisher PWB
Check the following:
ï
Eject Roll for wear and a drive failure
ï
Eject Shaft for wear and a drive failure
ï
Each Driver Gear for wear, a drive failure, and breakage
ï
Belt for disengagement, breakage, and improper tension
Replace the Finisher PWB
(PL
17.13).
Prelaunch Training/Review
DC1632/2240
(PL
17.13).
(PL
17.8).
(PL
17.13).
(PL
17.8).
(PL
17.8).
(PL
17.8).
(PL
17.8).
Eject Clamp Home Sensor
Figure 1 Component Location
Figure 2 Set Clamp Home Sensor
Figure 3 Set Clamp Solenoid
6/02
2-225
Set
Clamp
Home
Sensor
Set
Clamp
Solenoid
Status Indicator RAPs