9-358 Full Toner Sensor

The Full Toner Sensor detects a full toner condition.
Initial Actions
ï
Ensure that the Waste Toner Cartridge is not full.
ï
Check the sensor for toner contamination and foreign substances.
Procedure
Remove the Full Toner Sensor from the bottle. Enter dC330 [009-150]. Block and unblock the
Full Toner Sensor (PL 4.1). The display changes state.
Y
N
Go to OF 99-2 Transmissive Sensor RAP.
Replace the MCU PWB. (PL 13.1)
Figure 1 The Full Toner Sensor
Prelaunch Training/Review
DC1632/2240

9-360 Yellow Drum Cartridge Communication

A communication failure with the Yellow Drum Cartridge was detected.
Initial Actions
Check that the Yellow Drum Cartridge is seated correctly.
Procedure
Enter
dC330
[009-151 Drum (Y) Data]. The display is H.
Y
N
Check the wires and connectors. If the check is OK, replace the Yellow Drum Cartridge
(refer to Section 6,
Machine
Consumables).
Replace the MCU PWB (PL 13.1).
Figure 1 Drum Y Communication