Ess Ram Dimm #3 W/R Check Failure; Ess Standard Ram Error - Xerox DocuColor 1632 Service Manual

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

103-336 ESS RAM DIMM #3 W/r Check Failure

A failure was detected during Read/Write Check of the ESS RAM DIMM #3.
Procedure
Turn the power OFF/ON. The fault is cleared.
Y
N
Remove and replace the ESS RAM DIMM #3.
If the problem continues, replace the ESS ROM DIMM #3
Return to Service Call Procedures.
Prelaunch Training/Review
DC1632/2240

103-337 ESS Standard RAM Error

An error was detected in the ESS built-in standard RAM.
Procedure
Turn the power OFF/ON. The fault is cleared.
Y
N
Replace the ESS PWB (PL 13.1).
Return to Service Call Procedures.
6/02
2-359
Status Indicator RAPs
103-336, 103-337

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 2240