Xerox DocuColor 1632 Service Manual page 423

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

116-380 MF UI Cont Soft
Fatal error of MF UI cont
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the ESS software.
If the problem continues, replace the ESS PWB
Prelaunch Training/Review
DC1632/2240
(PL
13.1).
116-381 Data Link Layer Error between Cont and UI
Panel
Controller - MF UI panel: Communication error on the Data Link layer
At the communication between the ESS and Panel, the ESS detected an initialization error of
SCOPE, a message sending error, or retrieve error of the received data.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the ESS or Panel software.
If the problem continues, replace the ESS PWB
If the problem continues, replace the Control Panel
6/02
2-393
(PL
13.1).
(PL
18.2).
Status Indicator RAPs
116-380, 116-381

Hide quick links: