Xerox DocuColor 1632 Service Manual page 417

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

116-366 Report Generator Soft
An operation failure of the Report Generator
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Replace the ESS PWB
(PL
13.1).
Prelaunch Training/Review
DC1632/2240
116-367 Parallel I/F Soft
Overall fatal errors of the Parallel
Due to an error during the software processing, the subsequent processes cannot be per-
formed.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Perform re-installation of the ESS software.
If the problem continues, replace the ESS PWB
6/02
2-387
(PL
13.1).
Status Indicator RAPs
116-366, 116-367