5-903 Power On Exit Sensor
At Power On, the DADF Exit Sensor detected a document when the Top Cover/platen Interlock
was closed.
Procedure
Check the following in dC330.
ï
[5-115] DADF Exit Sensor
The component is good.
Y
N
Go to the appropriate circuit and check the component.
Check that the voltage at the customer outlet is in specification and does not drop during
machine start.
Figure 1 Exit Sensor CD
Prelaunch Training/Review
DC1632/2240
6/02
2-79
Status Indicator RAPs