REP 5.2 Registration Gate Solenoid
Parts List on
PL 20.2
Removal
To avoid personal injury or shock, do not perform repair or adjustment activities with
the power switch on or electrical power applied to the machine.
1.
Remove Front Cover (PL 20.1).
2.
Remove Registration Gate Solenoid (Figure 1).
a.
Disconnect connector.
b.
Release clamps (2) and remove wire.
c.
Loosen screws (2).
d.
Remove Registration Gate Solenoid.
Screws (2)
Figure 1 Removing Registration Gate Solenoid
Repairs and Adjustments
REP 5.2
WARNING
Connector
Clamps (2)
6/02
4-18
Prelaunch Training/Review
DC1632/2240