Xerox DocuColor 1632 Service Manual page 805

Prelaunch cse training/review
Hide thumbs Also See for DocuColor 1632:
Table of Contents

Advertisement

760-xxx Regicon NVM List
Chain-Link
Name
760-006
Block
760-007
Y-MAG
760-008
M-MAG
760-009
C-MAG
760-010
K-MAG
760-011
Y-BAL
760-012
M-BAL
760-013
C-BAL
760-014
K-BAL
760-015
Y-Skew misregistration
760-016
M-Skew misregistration
760-017
C-Skew misregistration
760-018
K-Skew misregistration
760-019
Y-XSO
760-020
M-XSO
760-021
C-XSO
760-022
K-XSO
760-023
Y-YSO
760-024
M-YSO
760-025
C-YSO
760-026
K-YSO
760-027
Regi Con/Circum. Length Correction
implement SW
760-028
RC Start Temp
Prelaunch Training/Review
DC1632/2240
Table 15 Chain 760
Default
Range
Description
3
0~4
Threshold of pattern valid no. of Blocks. Fail occurs if the value is not corrected below the Threshold.
716
0~1432
Adjusts the Fast Scan direction image 100% magnification by switching the average frequency of each ROS
Video lock. (4 Colors/Correction Resolution Ability = 1/4 Pixel unit)
716
0~1432
Adjusts the Fast Scan direction image 100% magnification by switching the average frequency of each ROS
Video lock. (4 Colors/Correction Resolution Ability = 1/4 Pixel unit)
716
0~1432
Adjusts the Fast Scan direction image 100% magnification by switching the average frequency of each ROS
Video lock. (4 Colors/Correction Resolution Ability = 1/4 Pixel unit)
716
0~1432
Adjusts the Fast Scan direction image 100% magnification by switching the average frequency of each ROS
Video lock. (4 Colors/Correction Resolution Ability = 1/4 Pixel unit)
421
0~842
Adjusts the Left Right Magnification with respect to Fast Scan direction image center by changing the slant of
ROS Video Lock Sweep. (4 Colors/Correction Resolution Ability = 1/8 Pixel unit)
421
0~842
Adjusts the Left Right Magnification with respect to Fast Scan direction image center by changing the slant of
ROS Video Lock Sweep. (4 Colors/Correction Resolution Ability = 1/8 Pixel unit)
421
0~842
Adjusts the Left Right Magnification with respect to Fast Scan direction image center by changing the slant of
ROS Video Lock Sweep. (4 Colors/Correction Resolution Ability = 1/8 Pixel unit)
421
0~842
Adjusts the Left Right Magnification with respect to Fast Scan direction image center by changing the slant of
ROS Video Lock Sweep. (4 Colors/Correction Resolution Ability = 1/8 Pixel unit)
500
0~1000
100=1 rotation. 500 and above=CW direction, Below 500=CCW direction
500
0~1000
100=1 rotation. 500 and above=CW direction, Below 500=CCW direction
500
0~1000
100=1 rotation. 500 and above=CW direction, Below 500=CCW direction
500
0~1000
100=1 rotation. 500 and above=CW direction, Below 500=CCW direction
236
0~472
Adjusts the Fast Scan direction write start position by the No. of Video Locks from SOS Signal. (4 Colors/Cor-
rection Resolution Ability = 1 Pixel unit)
236
0~472
Adjusts the Fast Scan direction write start position by the No. of Video Locks from SOS Signal. (4 Colors/Cor-
rection Resolution Ability = 1 Pixel unit)
236
0~472
Adjusts the Fast Scan direction write start position by the No. of Video Locks from SOS Signal. (4 Colors/Cor-
rection Resolution Ability = 1 Pixel unit)
236
0~472
Adjusts the Fast Scan direction write start position by the No. of Video Locks from SOS Signal. (4 Colors/Cor-
rection Resolution Ability = 1 Pixel unit)
237
0~474
Adjusts the Slow Scan direction write start position by the No. of LS Signal Counts from the ROS/Image/Patch
Start Signal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
237
0~474
Adjusts the Slow Scan direction write start position by the No. of LS Signal Counts from the ROS/Image/Patch
Start Signal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
237
0~474
Adjusts the Slow Scan direction write start position by the No. of LS Signal Counts from the ROS/Image/Patch
Start Signal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
237
0~474
Adjusts the Slow Scan direction write start position by the No. of LS Signal Counts from the ROS/Image/Patch
Start Signal. (4 Colors/Correction Resolution Ability = 1 Pixel unit)
3
0~3
For check during servicing etc. 0 = Does not perform Regi Control nor Circumference Length Correction 1 =
Performs Regi Control, does not perform Circumference Length Correction 2 = Does not perform Regi Control,
performs Circumference Length Correction 3 = Performs Regi Control and Circumference Length Correction
40
10~250
Threshold of (Normal) Regi Control Implementation Temperature difference. Value on the left is 10 times of the
Temperature. (0.1 Degree Celsius interval)
6/02
6-41
General Procedures and Information

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Docucolor 2240

Table of Contents