G3V4vs/R5vs/R6vs to Avaya Communication Manager
Task List: DEFINITY vs to Avaya Communication Manager
Disable scheduled maintenance and alarm
origination [from G3V4vs/R5vs/R6vs]
Return to Task List
1
To prevent scheduled daily maintenance from interfering with the update or upgrade, type
change system-parameters maintenance
2
If scheduled maintenance:
— has begun: set the Stop Time field to 1 minute after the current time.
— has not begun: set the Start Time field to at least 8 hours after the upgrade starts.
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in
unnecessary trouble tickets.
3
Type neither in the Alarm Origination to OSS Numbers field and press Enter.
Return to Task List
Check link status [from G3V4vs/R5vs/R6vs]
Return to Task List
1
Type
display communication-interface links
2
Record the enabled links.
3
Type
status link <number>
4
Check the following items and record which links are in service. You will need this information
after the upgrade.
— ISDN
— BX25
— AUDIX links
— CMS links at both ends (also check the recovery time)
— ASAI links at the DEFINITY ECS end
5
Repeat Steps 3 and 4 for each enabled link.
Return to Task List
152
and press Enter.
and press Enter.
and press Enter.