Disable Scheduled Maintenance And Alarm Origination [From G3V4Vs/R5Vs/R6Vs]; Check Link Status [From G3V4Vs/R5Vs/R6Vs] - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

G3V4vs/R5vs/R6vs to Avaya Communication Manager
Task List: DEFINITY vs to Avaya Communication Manager
Disable scheduled maintenance and alarm
origination [from G3V4vs/R5vs/R6vs]
Return to Task List
1
To prevent scheduled daily maintenance from interfering with the update or upgrade, type
change system-parameters maintenance
2
If scheduled maintenance:
— has begun: set the Stop Time field to 1 minute after the current time.
— has not begun: set the Start Time field to at least 8 hours after the upgrade starts.
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in
unnecessary trouble tickets.
3
Type neither in the Alarm Origination to OSS Numbers field and press Enter.
Return to Task List

Check link status [from G3V4vs/R5vs/R6vs]

Return to Task List
1
Type
display communication-interface links
2
Record the enabled links.
3
Type
status link <number>
4
Check the following items and record which links are in service. You will need this information
after the upgrade.
— ISDN
— BX25
— AUDIX links
— CMS links at both ends (also check the recovery time)
— ASAI links at the DEFINITY ECS end
5
Repeat Steps 3 and 4 for each enabled link.
Return to Task List
152
and press Enter.
and press Enter.
and press Enter.
SI Installation and Upgrades
June 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1

Table of Contents