Install Fiber Optic Cable Pass-Thru Kit for SCC1 (Single-Carrier) Cabinets
Duplicated DS1C Converter Complex Administration for TN574 Circuit Packs
Duplicated DS1C Converter Complex Administration
for TN574 Circuit Packs
Return to Task List
Figure 42, Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1 Converter Complex
Administration) (page 3 of 3),
Page 3 appears when the Is one endpoint remoted via a DS1 Converter Complex? field is yes and
duplication is enabled.
NOTE:
When you administer DS1 Converter TN1654 circuit packs, different fields display.
For field definitions of the fields displayed on page 3 of the Fiber Link Administration form, see
Converter Complex Administration for TN574 Circuit
Figure 42: Fiber Link Administration form for TN574 Circuit Pack (Duplicated DS1
Converter Complex Administration) (page 3 of 3)
add fiber-link next
DS1CONV Board Location: 01C01
DS1CONV Board Type: TN574
Passes Far-end Clock?
Digital Data Compatible?
DS1CONV-1 Line Compensation:
DS1CONV-2 Line Compensation:
Facility B Circuit ID: 01112343
Return to Task List
218
on page 218 allows you to admininster the DS1 converter.
FIBER LINK ADMINISTRATION
B-PNC DS1 CONVERTER (DS1CONV) ATTRIBUTES
DS1 CONVERTER FACILITIES
A
Facility Installed?
yes
yes
yes
Line Coding:
ami-zcs
Framing Mode:
esf
1
1
Packs.
Page 3 of 3
DS1CONV Board Location: 02C01
DS1CONV Board Type: TN574
B
C
D
no
no
no
yes
yes
yes
yes
yes
yes
ami-zcs
ami-zcs
ami-zcs
esf
esf
esf
1
1
1
1
1
1