Disable Scheduled Maintenance And Alarm Origination [From G3V4]; Record All Links And Remove Only Isdn Interface Links [From G3V4] - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

G3iV4 to Avaya Communication Manager
Task List: G3iV4 to Avaya Communication Manager
Disable scheduled maintenance and alarm
origination [from G3V4]
Return to Task List
1
To prevent scheduled daily maintenance from interfering with the update or upgrade, type
change system-parameters maintenance
2
If scheduled maintenance:
— has begun: set the Stop Time field to 1 minute after the current time.
— has not begun: set the Start Time field to at least 8 hours after the upgrade starts.
CAUTION:
If you do not disable Alarm Origination, the system may generate alarms, resulting in
unnecessary trouble tickets.
3
Type neither in the Alarm Origination to OSS Numbers field and press Enter.
Return to Task List
Record all links and remove only ISDN
interface links [from G3V4]
Return to Task List
For R7 and later, ISDN links move to the Net Packet circuit pack. They are not retranslated. If you are
upgrading from any release earlier than R7, you remove the ISDN links and do not readminister them.
NOTE:
Any BX.25 adjunct links to adjuncts (for example, CMS, AUDIX, INTUITY, or others)
that are to be retained will still reside on the existing TN765 processor interface (P/I) in
the designated P/I slot. Remove the TN765 P/I only if the sales team has specified that all
adjunct connectivity is being migrated to a TN799 Control LAN (C-LAN) circuit pack.
Use this procedure to identify, record, and remove the ISDN links from the communication link and
communication processor forms:
1
Type
display communication-interface links
this form, note them.
2
For each link where the Prot field is ISDN, record the information in all fields.
If you must back out of the upgrade, you will need this information.
3
For each ISDN link, type
4
Type
change communication-interface links
5
For each link where the Prot field is ISDN, type n in the Enable field and press Enter.
6
Type
display communication-interface processor-channels
76
and press Enter.
and press Enter. If any links were administered on
busyout link
[
link
] and press Enter.
and press Enter.
and press Enter.
SI Installation and Upgrades
June 2004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1