Verify System Status; Disable Scheduled Maintenance And Alarm Origination To Inads - Avaya CMC1 Installation Manual

Avaya cmc1 media gateways
Table of Contents

Advertisement

Task Table

Verify System Status

1. Type display alarms and press
the needed corrective actions.
2. Type display errors and press
error 18s that identify the busy-outs placed by the customer.
Restore the customer-placed busy-outs after you have upgraded the
system.
3. Execute the following commands and verify that the information is correct:
list station
list trunk-group
list hunt-group
list data-module
list announcements
If any command does not complete successfully, escalate the problem
immediately.
Disable Scheduled Maintenance and Alarm
Origination to INADS
1. Type change system-parameters maintenance and press
2. If scheduled maintenance has begun, set the Stop Time field to 1 minute
after the current time.
or
If scheduled maintenance has not begun, set the Start Time field to a
time after the upgrade will be completed. For example, if you start the
upgrade at 8:00 p.m. and the upgrade takes 90 minutes, set the Start
Time field to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
3. Type neither in the Alarm Origination to OSS Numbers field and
press
NOTE:
Disabling alarm origination prevents the system from generating
alarms, thus preventing unnecessary trouble tickets.
For some DEFINITY ECS software versions, set the Cleared
Alarm Notification and Restart Notification fields to
disable before pressing
555-233-118
Enter.
Enter
. If the system is not alarm-free, take
Enter
. Examine the error log and record the
Enter
.
Issue 7 November 2003
.
Enter
3-13