Affix Label [From R5/R6/R7/R8Si]; Verify The Upgrade [From R5/R6/R7/R8Si] - Avaya MCC1 Installation And Upgrades

Media gateways installation and avaya definity server si upgrades made easy
Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Affix label [from R5/R6/R7/R8si]

Return to Task List
1
Affix the circuit pack position label (designation strip) to the front of the cabinet.

Verify the upgrade [from R5/R6/R7/R8si]

Return to Task List
1
Execute
2
Type
display alarms
If the system is not alarm-free, take the needed corrective actions.
3
Type
list configuration software-version
(duplex) and press Enter. Check the Memory Resident field to verify that it shows the correct
software load.
4
Type
display communication-interface links
Status each of the links.
NOTE:
ISDN-PRI D-channel links no longer appear on this screen. (For release 7 and later,
ISDN-PRI resides on the network packet circuit pack.) For release 7 and later, the only
way to determine if an ISDN-PRI D-Channel is up is to use the status signaling group
command.
5
Type
list signaling-group
Validate that all the signal groups that should be operational are in service.
6
Execute the following commands and verify that the information is correct:
list station
list trunk-group
list hunt-group
list data-module
For upgrades from systems later than G1,
For a system with Expert Agent later than G3V3,
7
For duplicated systems only, execute
Return to Task List
SI Installation and Upgrades
June 2004
status system 1
and verify that the system is in a normal state.
and press Enter.
and press Enter. For each signal, execute
R5/R6/R7/R8si to Avaya Communication Manager
Task List: R5/R6/R7/R8si to Avaya Communication Manager
(simplex) or
list configuration software-version long
and press Enter.
list ars analysis
list agent
status system 1
.
status signal <number>
125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1